Gland packing: AP 3011 DRY:

Gland packing braided by expanded PTFE yarn GORE-TEX

Specifications:

  • T : -200°C / + 280 °C
  • Pressure:
  • centrifugal pumps: 30 bar
  • pistonpumps: 30 bar
  • valves: 250 bar
  • PH : 0 -14
  • V: 18 m/s

Application:

Used for the sealing of pumps, mixers, valves and sliders.

Advantages:

The AP 3011 DRY Packing is suitable to be used both for acids and for bases.
The packing has a very low shrinkage, does not lose volume, which is a guarantee for a high degree hermetically sealed compound.